Watts Premier FILTER-PURE Spezifikationen Seite 16

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 22
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 15
Page 16
TROUBLE SHOOTING
Problem Cause Solution
1. Low/Slow Production Low Water Pressure Assure a minimum of 40 psi incoming water pressure.
Premier sells a booster pump if home water pressure is
low. Maker sure water supply is turned on and Adapta
Valve is all the way open
Crimps in tubing Check tubing and straighten or replace as necessary.
Clogged pre- lters Replace pre- lters.
Fouled membrane Replace membrane and ow restrictor.
2. Milky colored Water Air in system Air in the system is a normal occurrence with initial
start up of the RO system. This milky look will
disappear during normal use within 1-2 weeks. If
condition reoccurs after lter change, drain tank 1 to 2
times.
3. Water constantly Low water pressure See #1 Above
running unit will not
shut off Crimp in supply tube Check tubing and straighten or repair as necessary
4. Noise / Water from Crimp or restriction in Check tubing and straighten or repair as necessary.
faucet vent hole or noise drain line Straighten all drain lines. Clear blockage. Cut off any
from drain Excess tubing
Drain tube clogged Caused from dishwasher or garbage disposal.
Disconnect the 3/8” black line at the drain, clean the
3/8” black line out with a wire, then reconnect. Blowing
air through the line will not always remove the clog.
5. Small amount of water in System starting up Normally it takes 6-10 hours to ll tank. Note: low
storage tank incoming water pressure and/or temperature can
drastically reduce production rate.
Low water pressure See #1 above.
To much air in tank Tank air pressure should be 5 psi when empty of water.
If below 5 psi add air or bleed if above 5 psi.
Check only when tank is empty of water.
See previous page.
6. Water leaks from the lter / Not properly inserted Re-insert the lter / membrane housing.
membrane housing
7. Low water ow from faucet Check air in tank Use a Digital Air Gauge for best results. The empty
tank pressure should be 5-7 psi. To reset the air pressure
in the tank turn off water supply and drain tank by
opening faucet. When water stops owing out of the
faucet. Remove schrader valve cover pump air into
tank until water stops owing from the faucet. Release
the air out of the schrader valve until you reach 5-7 psi.
Replace schrader valve cover. Turn on Water.